Meet your state's pump-to-attendant communication requirement without running a single wire.
Many states and local municipalities require gas stations to provide customers with a way to reach an attendant from the pump. This MURS wireless intercom kit provides that connection in minutes—no trenching, no electrician, and no FCC license required. Support one pump with a standalone system or connect two pumps to a single callbox. Need to expand? Additional pumps can easily be added as your station grows.

Call 888-298-9489 — we'll help make sure you get every component right the first time.
How Many Callboxes Do You Need?
- Single pump: one callbox per pump.
- Two adjacent pumps: one shared callbox works for both in many states (check with your state or city regulations).
- Full station or multi-pump lot: add additional callboxes on their own MURS/CTCSS channel (5 available channels, 38 privacy codes, use RT1146 handheld for up to 16 pumps)
Key Features
- Wireless, 2-way communication — no trenching or construction required
- Rugged and weatherproof — durable, high-impact, gasket-sealed enclosure for outdoor use
- Flexible power options — 3 D-cell alkaline batteries, or external 12V DC for always-on intercom mode
- Long battery life — up to 6,000 transmissions on batteries alone (up to ~1 year of typical use)
- License-free MURS frequencies — no FCC license needed
- High-quality, high-gain audio — adjustable volume, clear even in loud environments; 1-mile line-of-sight range
- Easy installation — standard flange mount brackets include, optional pole mounting brackets available
- Low battery and power-fail alerts — tone when batteries run low or 12V power is lost
- Tamper- and vandal-resistant — machined aluminum push-to-talk button, internal antenna
- Compact footprint — callbox: 7"H x 5.5"W x 3"D · base station: 1.4"H x 3.8"W x 5.6"D

How It Works
Each callbox runs on the MURS radio band, which the FCC lets anyone use license-free. Out of the box, one callbox talks to one handheld radio or base station — plug-and-play, no configuration needed. If you're running more than a couple of callboxes, our RT1146 handheld radio can be programmed with privacy codes so each callbox only responds to its intended radio, letting you run up to 16 callboxes across the 5 available MURS frequencies without them talking over each other.
Most single- or two-pump installs never need to touch this configuration. It matters most for larger stations running several callboxes at once — see the technical detail below if that's you.
Technical Details: Channels, CTCSS & Multi-Callbox Setup
Multi-Channel Communication
The outdoor callboxes use MURS (Multi-Use Radio Service) frequencies, which are FCC-license-free. MURS provides 5 base frequencies; adding CTCSS (Continuous Tone-Coded Squelch System) privacy codes expands this to 16 distinct channels on our RT1146 handheld radio, so devices can be configured to respond only to their intended traffic and reduce interference between callboxes.
Practical Configuration Examples
- Configure two callboxes on the same frequency using different CTCSS codes
- Assign a unique CTCSS code to each callbox so only the intended one responds
- Receive calls from up to 16 wireless callboxes across the 5 MURS frequencies
Channel Planning Note
CTCSS codes provide selective communication, but two callboxes transmitting at the exact same moment on the same frequency can still interfere with each other. We can help you plan a channel layout for larger multi-pump installs.
Power & Operating Modes
- Auto Turnoff mode (factory default, battery-powered): callbox sleeps to save power, wakes instantly when the button is pressed. Cannot receive incoming calls in this mode.
- Intercom mode (requires external 12V DC): callbox stays on at all times, so attendants can call out to the pump as well as receive calls.
- Power consumption: Off 0mA · Sleep 3mA · Standby 93mA · Receive 300mA · Transmit low 500mA · Transmit high 760mA
- High/low power output: field-programmable when on external 12V DC; battery mode operates in low power only
Meeting State Pump Communication Requirements
A growing number of states or even local municipalities require gas stations to provide a working method for customers to reach an attendant from the pump island. This kit is designed specifically to satisfy that requirement wherever running conduit or wiring to each pump isn't practical — check your state's specific fire marshal or weights-and-measures regulations for the exact wording that applies to your location.
Call 888-298-9489 — we'll help make sure you get every component right the first time.
Gas Station Intercom FAQs
Q: Can I power the callboxes using the fuel pump's power supply?
A: Yes, as long as the fuel pump provides 12 volts DC. You'll need the optional RT1097 power adapter cable.
Q: Can I call a callbox at the pump while it's running on D batteries?
A: No. To conserve battery power, the callbox stays in sleep mode until a customer presses the button, which wakes it up and enables two-way communication.
Q: How do I add more intercoms to this kit?
A: Check the Related Items section below for the individual callbox unit. You can add as many as you need — as long as they're all set to the same channel, there's no limit.
Q: Can one receiver work with multiple outdoor units in the MURS Gas Station Intercom system?
A: Yes. Multiple outdoor units can call into multiple indoor units. If the system is mainly for customers calling in, each outdoor unit can be set to auto-turnoff mode so it sleeps when idle. All units would share the same frequency, and only the calling intercom's conversation is heard. Alternatively, you can program up to 5 units on separate channels for independent calling, and by adding privacy codes to those 5 channels, the system can support up to 16 pumps.






